Fluke 5520 specifications
WebFluke 5522A. Model Specifications: Manufacturer(s): Fluke: Instrument Model: 5522A: Description: Multi-Product Calibrator: Instrument Family: 5XXX Series: Instrument Type(s): Calibrator: Application Area(s): Test and Measurement: Drivers Available For This Instrument Model ADE WebProduct Highlights. Fluke 5520A Multi-Product Calibrator expands your workload coverage even further with improved accuracy in nearly all areas. The 5520A offer the excellent stability, linearity and low noise performance you expect from Fluke. And each unit is shipped with test data and a certificate of traceability to nationally recognized ...
Fluke 5520 specifications
Did you know?
WebIn terms of specifications, the Fluke 5520A calibrator offers DC and AC volts to 1000 V, DC and AC current to 20 A, outputs four different waveforms (sine, square, triangle, and truncated sine), resistance to 1100 Mohm, capacitance to 110 mF, simulated power to 20.5 kW with phase control, simulate and measure nine different thermocouple types, … WebAll specifications apply for the temperature and time period indicated. For temperatures outside of tcal + 5 °C (tcal is the ambient temperature when the 5500A was calibrated), the temperature coefficient is less than 0.1 times the 90-day specifications per °C (limited to 0 °C to 50 °C). These specifications also assume the 5500A Calibrator ...
Web3 Fluke Corporation Fluke 5820A Oscilloscope Calibrator Specifications Leveled sine wave function > 600 MHz (2.1 GHz option) Leveled Sine Wave Characteristics into 50 W Frequency Range 10 MHz (reference) 600 MHz to 1.1 GHz 1.1 GHz to 1.6 GHz 1.6 GHz to 2.1 GHz Amplitude range (p-p) 5 mV to 3.5 V 1-year absolute amplitude uncertainty, tcal … Webanalog and digital interface for the Fluke 5725A Amplifier. 6 IEEE-488 Connector is a standard parallel interface for operating the 5500A in remote control on the IEEE-488 bus. 7 WARNING To avoid shock hazard, connect the factory supplied three-conductor line power cord to a properly grounded power outlet. Do not use a two-conductor
WebGeneral Specifications Warm up Time Twice the time since last warmed up, to a maximum of 30 minutes Settling Time Less than 5 seconds for all functions and ranges except as noted Standard InterfacesIEEE-488 (GPIB), RS-232 Temperature Performance Operating: 0°C to 50°C Calibration (tcal):15°C to 35°C Storage: -20°C to 70°C Temperature ... WebThe Fluke 5520A Multi-Product Calibrator is not only a powerful testing device but a complete tool for all electrical calibrations. Additional improvements allow the device to …
Web19 rows · 5522A features at a glance. Calibrates a wide variety of electrical test equipment. Robust ...
Web5520A Black and White Extended Specifications Fluke Corporation 1 5520A Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or twice the time the 5520A has been turned off. (For example, if the 5520A has been turned off for 5 minutes, the warm-up … chipz productionWebGeneral Specifications Warm up Time Twice the time since last warmed up, to a maximum of 30 minutes Settling Time Less than 5 seconds for all functions and ranges except as … chip znuff wigWebIts improved accuracy, expanded ranges, and added features, including current to 20A and pressure measurement, as well as its capability to calibrate 51 ⁄2 and 61 ⁄2 digit multimeters, means the 5520A can cover … chipz twitchWebFluke 5520A High Performance Multi-Product Calibrators The Fluke 5520A builds on the 5500A’s capabilities, extending its workload coverage even further. Its improved accuracy, expanded ranges, and capability to calibrate 5 1/2 and 6 1/2 digit multimeters can cover virtually all your high-performance workload, including: graphic design city postersWebFluke 5520A. High Performance Multi-Product Calibrators. The Fluke 5520A builds on the 5500A’s capabilities, extending its workload coverage even further. Its improved … graphic design classes atlantaWebThe 5520A includes current to 20 A and pressure measurement, as well as its capability to calibrate 5 1/2 and 6 1/2 digit multimeters, means the 5520A can cover virtually all your high-performance workload. It has options to calibrate oscilloscopes to 300 MHz, 600 MHz, or 1.1 GHz. Specifications. graphic design church jobsWebThe Fluke 5520A Calibrator builds on the 5500A's capabilities, extending its workload coverage even further. Its improved accuracy, expanded ranges, and capability to calibrate 5 1/2 and 6 1/2 digit multimeters can cover virtually all your high-performance workload, including: Handheld and bench meters (analog and digital) up to 6 1/2 digits. graphic design christian colleges